05.png

Marine LSOH Power Cable

船用电缆.jpg







1.Standard:

IEC 60092-350-2014    IEC 60092-353-2016    GB/T 9331-2008

2.Application:

Used for the power transmission in ships & on oil platform and other over - water buildings as well as power cables for port machineries.

3. Operational performance:

1).Rated Voltage:U0/U: 0.6/1kV

2). Minimum allowed bending radius for laying(D: outer diameter)

4D (D≤25mm);6D (D>25mm);

3). Maximum conductor temperature for continuous operation: ≤90℃

4). Minimum laying temperature:-20℃

4. Type & Model:

        Type

                                      Model

CEPF/SC/NC

EPR Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC

CEPJ/SC/NC

EPR Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant   Marine Power Cable  / SC/NC

CEPF86/SC/NC

EPR Insulated Non-cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH   Flame Retardant Marine Power Cable/ SC/NC

CEPJ85/SC/NC

EPR Insulated Cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH   Flame Retardant Marine Power Cable/ SC/NC

CEPF96/SC/NC

EPR Insulated Non-cross-linked Polyolefin Sheath Galvanized Steel Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH   Flame Retardant Marine Power Cable/ SC/NC

CEPJ95/SC/NC

EPR Insulated Cross-linked Polyolefin Sheath Galvanized Steel   Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH   Flame Retardant Marine Power Cable/ SC/NC

CEPFR/SC

EPR Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Flexible Power Cable/ SC

CEPJR/SC

EPR Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Flexible Power Cable/ SC

CJPF/SC/NC

XLPE Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/SC/NC

CJPJ/SC/NC

XLPE Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/SC/NC

CJPF86/SC/NC

XLPE Insulated Non-cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH Flame Retardant   Marine Power Cable/ SC/NC

CJPJ85/SC/NC

XLPE Insulated Cross-linked Polyolefin Sheath Tinned Copper   Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC

CJPF96/SC/NC

XLPE Insulated Non-cross-linked Polyolefin Sheath Galvanized Steel Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH Flame Retardant   Marine Power Cable/ SC/NC XLPE

CJPJ95/SC/NC

XLPE Insulated Cross-linked Polyolefin Sheath Galvanized   Steel Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC XLPE XLPE

CJPFR/SC

XLPE Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/ SC

CJPJR/SC

XLPE Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant   Marine Power Cable/ SC

5.Fire Resistance:

Type of SC:  Up to standard of Class A Combustion Requirements of Bunched Flame Retardant as per IEC 60332-3 (IEC 60754-1,2;  IEC 61034-1,2;  IEC 60684-2)

Type of NC:  Up to standard of Class A Combustion Requirements of Bunched Flame Retardant as per IEC 60331-21 &

 IEC 60332-3 (IEC 60754-1,2;  IEC 61034-1,2;  IEC 60684-2)

6. Specs. Range

Core No.

Nominal Cross Section(mm2)

1

1-300

2

1-120

3

1-185

4-37

1-2.5

7.Remarks: 

special customizing is available.